Lundahl Mains transformer for Tube Amplifiers, LL2748
C-core mains transformer. The core is assembled with a small air-gap to compensate for any mains DC-unbalance. Estimated power rating 250 VA which can be increased with good cooling. Magnetic stray is extremely small if secondaries of the two coils are loaded identically.
Weight 2.5 kg
Copper resistance, no load output voltages and max recommended transformer current (rms) with primary connected to 230 V serial / 115V parallel and Sec 1 connected as above
Primary res. Serial/parallel: 7.5 Ohm / 1.9 Ohm
Sec 1: 36 Ohm / 443V 0.3A
Sec 2: 0.1 Ohm / 5.4V 4 A
Sec 3: 0.1 Ohm / 6.7V 2A
Sec 4: 0.1 Ohm / 5.4 V 4A
Sec 5: 0.1 Ohm / 6.7V 2A
Please note! Output current from rectifier: 63% of above with capacitor input rectifier, 95% of above with choke input rectifier.